Splitter3#

ThermoSysPro Version 4.2#

This component model is documented in Sect. 14.8 of the ThermoSysPro book.

Splitter3#

The static splitter is a cavity splitting an incoming flow into two or more exiting flows of adiabatic single-phase or homogeneous two-phase fluid.

Modelica component model#

The equations mentioned below are implemented in the component Splitter3, located in the WaterSteam.Junctions sub-library.
This component has 8 connectors:

  • Ce: fluid inlet,

  • Cs1: first fluid outlet,

  • Cs2: second fluid outlet,

  • Cs3: third fluid outlet,

  • Ialpha1: extraction coefficient imposing the fraction Ce1.Q/Cs.Q,

  • Ialpha2: extraction coefficient imposing the fraction Ce2.Q/Cs.Q,

  • Oalpha1: value of Ce1.Q/Cs.Q,

  • Oalpha2: value of Ce2.Q/Cs.Q.

If the connector Ialpha.x is not connected, then the fraction Cex.Q/Cs.q is not imposed.
If the connector Ialpha.x is connected, then Oalphax=Ialphax.

ThermoSysPro.WaterSteam.Junctions.Splitter3.svg

Nomenclature#

Symbol

Description

Unit

Definition

Modelica name

\(h_{\mathrm{i}}\)

Specific enthalpy of the fluid at the inlet of the splitter

\(\mathrm{J} / \mathrm{kg}\)

Ce.h

\(h_{\mathrm{o}_{1}}\)

Specific enthalpy of the fluid at outlet 1

\(\mathrm{J} / \mathrm{kg}\)

Cs1.h

\(h_{\mathrm{o}_{2}}\)

Specific enthalpy of the fluid at outlet 2

\(\mathrm{J} / \mathrm{kg}\)

Cs2.h

\(h_{\mathrm{o} 3}\)

Specific enthalpy of the fluid at outlet 3

\(\mathrm{J} / \mathrm{kg}\)

Cs3.h

\(\dot{m}_{\mathrm{i}}\)

Fluid mass flow rate at the inlet

\(\mathrm{kg} / \mathrm{s}\)

Ce.Q

\(\dot{m}_{\mathrm{o}_{1}}\)

Fluid mass flow rate at outlet 1

\(\mathrm{kg} / \mathrm{s}\)

Cs1.Q

\(\dot{m}_{\mathrm{o}_2}\)

Fluid mass flow rate at outlet 2

\(\mathrm{kg} / \mathrm{s}\)

Cs2.Q

\(\dot{m}_{\mathrm{o}_{3}}\)

Fluid mass flow rate at outlet 3

\(\mathrm{kg} / \mathrm{s}\)

Cs3.Q

\(\alpha_{1}\)

Extraction coefficient for outlet 1 (output of the model)

\(-\)

\(\frac{\dot{m}_{\mathrm{o}_{1}}}{\dot{m}_{\mathrm{i}}}\)

alpha1

\(\alpha_{2}\)

Extraction coefficient for outlet 2 (output of the model)

\(-\)

\(\frac{\dot{m}_{\mathrm{o}_{2}}}{\dot{m}_{\mathrm{i}}}\)

alpha2

\(\alpha_{\mathrm{o}_{1}}\)

Mass fraction coefficient for outlet 1

Ialpha1.signal

\(\alpha_{\mathrm{o}_{2}}\)

Mass fraction coefficient for outlet 2

\(-\)

Ialpha2.signal

Governing equations#

Static mass balance equation#

  • Validity domain:

\(\forall \dot{m}\)

  • Mathematical formulation:

\[0=\dot{m}_{\mathrm{i}}-\dot{m}_{\mathrm{o}_{1}}-\dot{m}_{\mathrm{o}_{2}}-\dot{m}_{\mathrm{o} 3}\]
  • Comments:

The value of \(\dot{m}_{\mathrm{o}_{1}}\) and \(\dot{m}_{\mathrm{o}_{2}}\) can be defined as a fraction of the input mass flow rate:
$\( \dot{m}_{\mathrm{o}_{1}} =\alpha_{\mathrm{o}_{1}} \cdot \dot{m}_{\mathrm{i}} \ \dot{m}_{\mathrm{o}_{2}} =\alpha_{\mathrm{o}_{2}} \cdot \dot{m}_{\mathrm{i}}\)$

This option enables to compute the mass flow rates at the outlets knowing the mass flow rate at the inlet.

Static energy balance equation#

  • Validity domain:

\(\exists \dot{m}\) such that \(\dot{m} \neq 0\)

  • Mathematical formulation:

\[0=\dot{m}_{\mathrm{i}} \cdot h_{\mathrm{i}}-\dot{m}_{\mathrm{o}_{1}} \cdot h_{\mathrm{o}_{1}}-\dot{m}_{\mathrm{o}_{2}} \cdot h_{\mathrm{o}_{2}}-\dot{m}_{\mathrm{o}_{3}} \cdot h_{\mathrm{o}_{3}}\]
  • Comments:

This equation is valid if at least one mass flow rate is nonzero. Otherwise, the mixing specific enthalpy inside the splitter is undefined.

References#

El Hefni, Baligh and Bouskela, Daniel (2019). Modeling and Simulation of Thermal Power Plants with ThermoSysPro, sect. 14.8. Springer Nature Switzerland AG.