DynamicCondenser#

ThermoSysPro Version 4.2#

This component model is documented in Sect. 9.5.4 of the ThermoSysPro book.

Dynamic condenser#

In the condenser, the cooling water flows inside the tube bundle, while the steam and condensate flow inside the cavity.
This model completes the simple dynamic condenser for it features the thermal exchanges between the fluid in the cavity and the cooling fluid flowing through the tube bundle.

Modelica component model#

The equations mentioned below are implemented in the component DynamicCondenser, located in the WaterSteam.HeatExchangers sub-library.
This component has 6 connectors:

  • C1vap: high-pressure vapor inlet,

  • C2vap: low-pressure vapor inlet,

  • C1: extra water inlet,

  • Ce1: cooling water inlet,

  • Ce2: cooling water outlet,

  • C2ex: condensed water extraction outlet.

The component is an assembly of a (monophasic) tube bundle, a heat exchanger wall, and a two-phase cavity sub-components.

ThermoSysPro.WaterSteam.HeatExchangers.DynamicCondenser.svg

Nomenclature#

See simple dynamic condenser .

Governing equations#

See simple dynamic condenser .

References#

El Hefni, Baligh and Bouskela, Daniel (2019). Modeling and Simulation of Thermal Power Plants with ThermoSysPro, sect. 9.5.4. Springer Nature Switzerland AG.